Warning : these high voltage products require the highest caution when using, notably never connect or disconnect a fed circuit.

 

5000 V   CAT I
transient overvoltages 2 kV
Reinforced insulation.    pollution degree 2    6 A

 

5 kiloVolt, measurement category I, transient overvoltages 2 kiloVolt, and reinforced insulation.

Type 5600/5600-HT


5 kiloVolt, measurement category I, transient overvoltages 2 kiloVolt, and reinforced insulation.

Type 5600/5500-HT


2 Ø4 mm male connectors lead. Lead equipped with clips into supple sheath at one end and with a Ø4 mm male connector at the other end.

 

 

 

 

5 kiloVolt, measurement category I, transient overvoltages 2 kiloVolt, and reinforced insulation.

P / N 5450-HT

5 kiloVolt, measurement category I, transient overvoltages 2 kiloVolt, and reinforced insulation.

Type 5500/5500-HT


Clips into supple sheath for Ø4 mm male connector lead (20 A). Lead with clips into supple sheath.

 

5 kiloVolt, measurement category I, transient overvoltages 2 kiloVolt, and reinforced insulation.

Type 5500-HT


                        
5 kiloVolt, measurement category I, transient overvoltages 2 kiloVolt, and reinforced insulation.

Type 5600-HT

Lead with clips into supple sheath at one end and bare wire extremity at the other end.

Please consult us.

Because this lead has got a bare wire extremity, it is not ready to be used. It needs to be standardized. So, clearance and creepage distance must be more than 51 mm.

Lead with a Ø4mm male connector at one end, and a bare wire extremity at the other end.

Please consult us.

Because this lead has got a bare wire extremity, it is not ready to be used. It needs to be standardized. So, clearance and creepage distance must be more than 51 mm.

 

Male connectors mechanically compliant with all Ø4 mm ELECTRO-PJP female connectors. Beware of electrical compliance: check and compare max. rated characteristics of each part, and keep only the lowest characteristic.

So, above Ø4 mm 5000 V male connectors can be mated to Ø4 mm ordinary female sockets. Few modifications are so required to keep away the female socket from any user touch.
Case of the Ø4 mm female flushing socket : an additional panel, drilled to enable connecting, and 32 mm (1.26 in) away from the sockets, keeps the conductors in a safe area.

Other specifications :

- colours red or black (grey cable)
- lead length 100 cm (39.4 in) or 150 cm (59.1 in)

 