Safety anti-error device : principle, to prevent operator from connecting a phase to earth (ground).

Ø4 mm sockets :

1000 Volt, measurement category III, and reinforced insulation. 600 Volt, measurement category II, and reinforced insulation. 1000 Volt, measurement category III, and reinforced insulation.
Ø4 mm male socket,
fixing with nut,
drilling Ø12 mm +0.1.
P / N 3268.
Ø4 mm male socket,
surface mount setting,
drilling Ø8 mm +0.1.
P / N 3284-MD.
Ø4 mm male socket,
fixing by press fit,
drilling metal Ø12.2 mm +0.2
drilling plastic Ø12.5 mm ±0.05.
P / N 3288.
new18-3.gif (3220 octets) new18-6.gif (2889 octets)
33 Volt alternative current and 70 Volt direct current non hazardous live voltages. 33 Volt alternative current and 70 Volt direct current non hazardous live voltages.
Uninsulated socket for test-point on metal frame.
P / N 3298/M.
Uninsulated socket for test-point on metal frame.
P / N 3298/F.

More anti error devices : Ø2 mm versions and Ø4 mm socket adapters.

 

Ø4 mm ground (earth) link leads :

1000 Volt, measurement category III, and reinforced insulation.

New design

Ø4 mm straight female - Ø4 mm straight female.
Type 2053-IEC to 2057-IEC.

.

1000 Volt, measurement category III, and reinforced insulation.

Ø4 mm stackable female - Ø4 mm stackable female.
Type 2073-IEC to 2077-IEC.

(Important information see foot note)

More anti error devices : Ø2 mm versions.

 

 

Other earth / ground accessories ...
Other earth / ground accessories ...

 

 

Important information :

Our Ø4 mm stackable connectors are compliant at 1000 V    CAT III   reinforced insulation   pollution degree 2    with IEC 1010-2-031 which is valid up to February 1st, 2005.

Then IEC 61010-031 standard will supersede it. It requires larger clearances and creepage distances which force to downgrade these connectors.
The new specifications will be 1000 V   CAT II    reinforced insulation   pollution degree 2
                                       and / or 600 V    CAT III   reinforced insulation   pollution degree 2.

 

Contact : Address  : Electro PJP   31 rue Julien Feuvrier   BP366   F-39105 Dole   France