Our 5800 test tips serie is built according to the IEC 61010-031 standard requirements. Their achievement needs a supplementary enclosure which prevents persons against access to hazardous parts with their fingers : IP2X.

IP2X test probes, with high breaking capacity fuse

IP2X test probes

New catalogue pages to download

IP2X test probes, with high breaking capacity fuse Télécharger notre page catalogue au format PDF d'Acrobat. :

 

600 Volt, measurement category III, and reinforced insulation.

Class CC fuse-holder test tip, Ø4 mm connectable tip - Ø4 mm female connector. P / N 5801-CC.

600 Volt, measurement category III, and reinforced insulation.

Example of standard fuse-holder test tip lead,
Ø4 mm connectable tip - Ø4 mm male straight connector with cable. Type 5807-Sd.

 

Specifications (details lower) :

 

Electrical specifications :

 

Fuse-holder test tips available in standard or class CC version :

Thanks to the anti-error device of these fuse-holder test tips, it is impossible to install a standard fuse in a class CC fuse-holder test tip.

10 x 38 mm (0.41 x 1.50 in) fuse specifications 10 x 38 mm (0.41 x 1.50 in) standard fuses 10 x 38 mm (0.41 x 1.50 in) class CC fuses
Voltage : 500 V 600 V
Currents range : 2 A, 6 A, 10 A, 16 A, et 20 A 2 A, 6 A, 10 A, 15 A, et 20 A
Breaking capacity See defintions a the page foot. : 120 kA (120 000 A) See defintions a the page foot. 200 kA (200 000 A) See defintions a the page foot.
Design : Fusible standard

(symmetrical)

Fusible classe CC

Anti-error device (rejection feature)

 

Light indicator of blown fuse :

An orange neon indicator lights when the fuse is blown.

 

Long and fine tip :

The length (26 mm, 1 in) and the fineness (Ø3.8 mm, 0.15 in) of the tip itself allow measurements in well bottom to 26 mm (1 in).


Retracted sleeve

 

Retractable and lockable sleeve :

A translucent sleeve gives tip a IP2X grade protection (according to IEC 60529 "Degrees of protection provided by enclosures (IP Code)", and prevents any accidental contact or touch. This sleeve is retractable by pulling the button to the back. It covers tip and locks automatically when button is released. It can also be held retracted by installing a special tool shipped with the fuse-holder test tip.


Sleeve covering the tip, IP2X protection


Sleeve retracted and held thanks to the special tool

 

Connectable test tip :

Thanks to its sleeve specially designed, the test tip can be safely connected to

It can be also connecte to basic Ø4 mm female sockets generally limited to non hazardous live voltages 33 V~ / 70 VDirect current..

 

Twinning use possible at 19 mm (0.75 in) pitch :

2 fuse-holder test tips can be twined thanks to guides.
The set creates 2 insulated poles with 19 mm (0.75 in) pitch compliant with pitch of some mains sockets and measuring device sockets.

 

Easy handling with gloves

 

Several types of available connections (in addition of Ø4 mm connectable tip) :

Available versions :

Class CC or standard fuse-holder test tip, with or without fuse
Ends of the fuse-holder test tip :
Ø4 mm connectable tip Ø4 mm female

P / N 5801-Sd (standard version) or P / N 5801-CC (class CC version)

Ø4 mm connectable tip cable with
  • Ø4 mm male straight connector
  • or Ø4 mm male right angled connector
  • or Ø4 mm male stackable
  • or Ø4 mm female straight connector
  • etc ...

Type 5807-Sd (standard version) or Type 5807-CC (class CC version)

 

Fuse-holder test tips shipped with cover unlocking special tool.

As required by the standard, for safety reasons, the cover can not be opened manually, and a special tool is required to open cover and replace fuse.

 

Other specifications :

 

 


 

IP2X test probes Télécharger notre page catalogue au format PDF d'Acrobat. :

600 Volt, measurement category IV, and reinforced insulation.

1000 Volt, measurement category III, and reinforced insulation.

Test tip, Ø4 mm connectable tip - Ø4 mm female connector. P / N 5802.

600 Volt, measurement category IV, and reinforced insulation.

1000 Volt, measurement category III, and reinforced insulation.

Test tip lead, Ø4 mm connectable tip - Ø4 mm male right angle connector. P / N 5812.

 

Specifications (details lower) :

 

Electrical specifications :

 

Long and fine tip :

The length (26 mm, 1 in) and the fineness (Ø3.8 mm, 0.15 in) of the tip itself allow measurements in well bottom to 26 mm (1 in).


Retracted sleeve

 

Retractable and lockable sleeve :

A translucent sleeve gives tip a IP2X grade protection (according to IEC 60529 "Degrees of protection provided by enclosures (IP Code)", and prevents any accidental contact or touch. This sleeve is retractable by pulling the button to the back. It covers tip and locks automatically when button is released.


Sleeve covering the tip, IP2X protection

Connectable test tip :

Thanks to its sleeve specially designed, the test tip can be safely connected to

It can be also connected to basic Ø4 mm female sockets generally limited to non hazardous live voltages 33 V~ / 70 VDirect current..

 

Twinning use possible at 19 mm (0.75 in) pitch :

2 fuse-holder test tips can be twined thanks to guides.
The set creates 2 insulated poles with 19 mm (0.75 in) pitch compliant with pitch of some mains sockets and measuring device sockets.

 

Easy handling with gloves

Other specifications :

 

 

Other test tips ...
Other test tips ...

 

Definitions (according to IEC 61010-031 standard, "Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031 Safety requirements for hand-held probe assemblies for electrical measurement and test") :

CAT III (measurement category III) : measurements performed in the building installation. Examples are measurements on distribution boards, circuit-breakers, wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example, stationary motors with permanent connection to the fixed installation.

Reinforced insulation and double insulation ( reinforced or double insulation. ) : protection insulation equal to 2 basic insulations at least. Required for any hand-held accessory.

Pollution : addition of foreign matter, solid, liquid or gaseous (ionized gazes), that may produce a reduction of dielectric strength or surface resistivity.

Pollution degree 2 : normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.

Breaking capacity : maximum current a fuse is able to break safely. The breaking capacity of the class CC fuses is more than one of the standard fuses ( 200 kiloAmpere against 120 kiloAmpere ) because they are intended to protect high power circuits. For this reason, they must not be replaced unintentionally by standard fuses else they may explode and create damages and hurts in case of overload.


Measurement accessories from the Electrop-PJP's "IP2X" range compliant with the above tips :

Click to go back to the top. Electro-PJP's "IP2X" range More information. "Very high safety" products - IP2X connection. Principle : to be able to connect the end of a lead's tip, unprotected, without any risk for the operator. Meanwhile, the usual safety rules must be applied. (download our catalogue page Download our catalogue page in Acrobat's PDF. )

 

Click to go back to the top.    Electro-PJP's "IP2X" range   More information.

Click to go back to the top.    Electro-PJP's "IP2X" range   More information.

1000 Volt, measurement category III, and reinforced insulation.
      6 A

1000 Volt, measurement category III, and reinforced insulation.
      6 A

Test-clips, connection clamps.


Clamps.

P / N 6005-IP2X

 

Test-clips, connection alligator clips.


Alligator clips.

P / N 6007-IP2X

 

 

Click to go back to the top.    Electro-PJP's "IP2X" range   More information.

Click to go back to the top.    Electro-PJP's "IP2X" range   More information.

1000 Volt, measurement category III, and reinforced insulation.
      6 A

1000 Volt, measurement category III, and reinforced insulation.
      20 A

Test-clips, connection hook.


Hook.

P / N 6008-IP2X

 

Rigid test-clips, connection alligator clips.


Alligator clips.

P / N 6009-IP2X

 

 

   Click to go back to the top.    Electro-PJP's "IP2X" range   More information.

Alligator clips.

1000 Volt, measurement category III, and reinforced insulation.
20 A

P / N 5004/LM-IP2X

 

Click to go back to the top.    Electro-PJP's "IP2X" range   More information. Click to go back to the top.    Electro-PJP's "IP2X" range   More information.
f11-40.gif (5370 octets) 1000 Volt, catégorie de mesure III, et isolation renforcée.
20 A

P / N 5450-IP2X

f11-41.gif (2115 octets) 1000 Volt, catégorie de mesure III, et isolation renforcée.
36 A

P / N 405-IP2X

Alligator clips under rubber sheath. Ø2 mm smooth test tip. Application : transforms a Ø4 mm connectable test tip into Ø2 mm smooth test tip.

 

Click to go back to the top.    Electro-PJP's "IP2X" range   More information.

Special right angle connectors. Ø4 mm smooth tip stripped on 19 mm (0.75 in) (P / N 60619-IP2X) or 25 mm (0.98 in) (P / N 60625-IP2X). Example of application : connects onto terminals.

600 Volt, measurement category III, and reinforced insulation.
20 A

P / N 60619-IP2X and 60625-IP2X

 

Contact : Address  : Electro PJP   31 rue Julien Feuvrier   BP366   F-39105 Dole   France
Phone : (33) Ø3 84 82 13 30,   Fax : (33) Ø3 84 82 40 48
E-mail : mail@electro-pjp.com,   Web : http://www.electro-pjp.com